Page 2
www.argo-hytos.com
Subject to change · 30.30-e · 0215
Characteristics
Operating pressure
0 ... 40 bar, min. 3 x 10
6
pressure cycles
Nominal pressure according to DIN 24550
0 ... 63 bar, min. 10
4
pressure cycles
Quasi-static operating pressure
Permissible pressures for other numbers of cycles
Operating pressure p [bar]
Number of cycles
Nominal flow rate
Up to 350 l/min (see Selection Chart, column 2)
The nominal flow rates indicated by ARGO-HYTOS are based on
the following features:
› closed by-pass valve at ν ≤ 200 mm
2
/s
› element service life > 1000 operating hours at an average fluid
contamination of 0,07 g per l/min flow volume
› flow velocity in the connection lines:
up to 100 bar ≤ 6 m/s
Filter fineness
5 µm(c) ... 30 µm(c)
β-values according to ISO 16889
(see Selection Chart, column 4 and diagram Dx)
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889
(see Selection Chart, column 5)
Hydraulic fluids
Mineral oil and biodegradable fluids
(HEEs and HETG, see info-sheet 00.20).
Temperature range
-30 °C ... +100 °C (temporary -40 °C ... +120 °C)
Viscosity at nominal flow rate
› at operating temperature:ν < 60 mm
2
/s
› as starting viscosity: ν
max
= 1200 mm
2
/s
› at initial operation:
The recommended starting viscosity can be read from the
diagram D (pressure drop as a function of the kinematic
viscosity) as follows: Find the 70 % ∆p of the cracking
pressure of the by-pass valve on the vertical axis. Draw a
horizontal line so that it intersects the ∆p curve at a point.
Read this point on the horizontal axis for the viscosity.
Mounting position
Preferably vertical, filter head on top
Connection
Threaded ports according to ISO 228 or DIN 13. Sizes see Selecti-
on Chart, column 6 (other port threads on request).
Electrical clogging indicator
› Switching voltage: max. 120 V AC / 175 V DC
› Switching current: max. 0,17 A AC / 0,25 A DC
› Switching power: max. 3,5 VA AC / 5 W DC
› Type of contact: Change-over
› Electrical protection: IP 65 (with mounted and secured
socket)